Three acronyms
Aeronautic uses guidance published by the National Weather Service. Our processing selects the appropriate guidance for each forecast period and presents it with its source and validity intact.
- MOS: Model Output Statistics
- Statistical equations that relate numerical weather model output to what was observed at a station, producing point guidance for that station.
- LAMP: Localized Aviation MOS Program
- Aviation guidance from NOAA's Meteorological Development Laboratory. The hourly bulletin is issued each hour at HH:30 UTC and covers hours 1–25, with an extended bulletin out to 38 hours for most elements, including ceiling and visibility.
- NBM: National Blend of Models
- NOAA's calibrated blend of model guidance. Its station text bulletins carry hourly periods near term, then three-hour periods.
Fresh LAMP first
For every hour LAMP covers, the timeline uses LAMP. Freshness is judged by the model run, not by when the bulletin was downloaded. A LAMP run is used for up to three hours (two missed cycles); an NBM run for up to six. A run stamped implausibly far in the future (beyond a ten-minute clock allowance) is rejected.
Each bulletin is also checked for structure. Every LAMP row must fall exactly at its run hour plus its projection hour, with no duplicates. If one row fails that check, the whole record is set aside rather than guessing which row is right.
How LAMP describes ceiling and visibility
LAMP expresses ceiling and visibility as categories. Each category is a range defined in NOAA's bulletin key. Aeronautic shows the lowest value in the selected category: the most conservative number the guidance supports, not a prediction of an exact height or distance.
| Category | NOAA range (ft) | Shown | Flight category |
|---|---|---|---|
| 1 | < 200 | <200 | LIFR |
| 2 | 200–400 | 200 | LIFR |
| 3 | 500–900 | 500 | IFR |
| 4 | 1,000–1,900 | 1000 | MVFR |
| 5 | 2,000–3,000 | 2000 | MVFR |
| 6 | 3,100–6,500 | 3100 | VFR |
| 7 | 6,600–12,000 | 6600 | VFR |
| 8 | > 12,000 or unlimited | >12000 | VFR |
The open-ended categories keep their meaning. Category 1 is bounded only above, so it displays <200 instead of inventing an exact height. Category 8 means a ceiling above 12,000 feet or no ceiling at all, so its display depends on the known cloud cover: with broken, overcast, or unknown cover it reads >12000; with a known few, scattered, or clear cover it shows that cover alone.
| Category | NOAA range (SM) | Shown |
|---|---|---|
| 1 | < ½ | <½ SM |
| 2 | ½ to < 1 | ½ SM |
| 3 | 1 to < 2 | 1 SM |
| 4 | 2 to < 3 | 2 SM |
| 5 | 3–5 | 3 SM |
| 6 | 6 | 6 SM |
| 7 | > 6 | +6 SM |
Visibility is also shown as one value: category 2 reads ½ SM, category 1 stays <½ SM, and category 7 stays +6 SM. Only the display collapses to one number. Internally, every row keeps the full category bounds and the raw model values.
Conditional ceiling and visibility
LAMP publishes two kinds of ceiling and visibility guidance. The ordinary categories, CIG and VIS, describe expected conditions at the hour. The conditional categories, CCG and CVS, are developed only from cases where precipitation was reported, so they describe conditions if precipitation occurs. NOAA's LAMP overview presents them as guidance on what the ceiling and visibility might lower to during precipitation.
Aeronautic follows LAMP's own categorical precipitation forecast. When PCO, the yes/no forecast of precipitation at the hour, is Y, the hour uses CCG and CVS. Otherwise it uses CIG and VIS. No additional probability threshold is applied.
| PCO | CIG | CCG | VIS | CVS | Shown |
|---|---|---|---|---|---|
| N | 5 | 3 | 6 | 4 | CIG 2000 · 6 SM · MVFR |
| Y | 5 | 3 | 6 | 4 | CIG 500 · 2 SM · IFR |
If precipitation is forecast but a conditional field is missing, the ordinary field is used and labeled as such. If the ordinary field is missing too, that one field comes from the NBM period covering the hour.
NBM for the rest of the timeline
NBM supplies hours that LAMP does not cover, out to 72 hours. Each NBM row keeps its native period, hourly or three-hour, split only where a LAMP hour already covers part of it, so rows never overlap. Each NBM period is checked against its own model run. Fields with no usable value remain unknown, and periods with no available guidance are left out rather than invented.
NBM visibility is numeric. A value below one mile is rounded down to the nearest reportable fraction, so 0.8 miles shows as ¾ SM, never as 1.
Flight category comes from the selected categories
For LAMP, the flight category is computed from the selected ceiling and visibility categories. For NBM, it uses the numeric guidance before display formatting. The more restrictive dimension governs. A known hazard is enough on its own: an IFR ceiling with missing visibility is IFR. VFR needs both dimensions known, so a high ceiling with unknown visibility is shown as unknown.
Every row says where it came from
Each hour carries its provenance: whether ceiling and visibility came from LAMP, LAMP conditional, or NBM; whether the precipitation gate was yes, no, or unknown; the LAMP and NBM model run times; the NOAA source URLs; and the raw codes behind the selection (CIG, CCG, VIS, CVS, PCO, and the NBM values for that hour).
Where MOS sits next to the TAF
In Aeronautic's fused weather timeline, observations and the official TAF come first. MOS never replaces TAF coverage; it extends the timeline past the end of the TAF and is labeled as guidance. The full MOS timeline also has its own view, alongside the TAF.
How we test it
Selection is a pure function of stored bulletins and a clock, so it is tested against frozen inputs: real archived LAMP and NBM bulletins plus synthetic hours like the one above. The tests check the precipitation gate, each fallback step, the lower-bound display, the open-ended categories, run freshness, and that every row has a valid time window with no overlap. Expected values belong to those frozen runs; live guidance changes with every cycle.
Primary sources
- LAMP products on NWS web services: NOAA MDL issuance cadence and projections
- LAMP bulletin key, v2.7.0: NOAA MDL element definitions and categories
- An Overview of the Redeveloped Localized Aviation MOS Program (LAMP): J. E. Ghirardelli, NOAA MDL, conditional ceiling and visibility (PDF)
- National Blend of Models: NOAA MDL